    层流手术室污染空调的维护和管理
    Maintenance and Management of Polluted Air Conditioning in Laminar Operating Room
    增强层流手术室污染空调的管理和维护,可以无效地控制手术室内的细菌浓度,避免医院感染,挺高手术的成功率。对污染零碎各参数做活期测试,掌握其运转质量。有方案地对初、中、过滤器停止清算、清洗或改换,及时对零碎停止消毒,是确保污染手术室平安运转的牢靠保证。
    Strengthening the management and maintenance of air-conditioning contamination in laminar flow operating room can effectively control the bacterial concentration in operating room, avoid hospital infection and improve the success rate of operation. Make a current test for every parameter of pollution fragments, and master its operation quality. It is a reliable guarantee to ensure the safe operation of the polluted operating room to stop liquidating, cleaning or replacing the primary, middle and high-efficiency filters in a planned way and to stop sterilizing the fragments in time.
    亲密凝视监测层流手术室的温、湿度,严厉地控制在它们的控制范围之内。温度的控制是一种控制细菌的无效手腕,是综合控制措施的一局部,即控制了空气中的细菌繁衍。也控制患者及医护人员经过排汗而排出的细菌,其意义决不单纯爲了外部人员的舒适感。手术室内的温度起到了控制细菌繁衍的作用。
    Close gaze monitors temperature and humidity in laminar flow operating rooms and strictly controls them. Temperature control is an ineffective way to control bacteria. It is a part of comprehensive control measures, that is, to control bacterial reproduction in the air. It also controls the bacteria excreted by patients and medical staff through perspiration. Its significance is not simply for the comfort of external staff. Temperature in the operating room plays a role in controlling bacterial reproduction.
    层流手术室装修
    绝对湿度控制不当,不只会促使人体发菌添加,还爲细菌的繁衍提供养分源。据研讨,绝对湿度50%时,细菌浮游10min后即死亡;绝对湿度更高或更低时,即便经过24h,大局部细菌还活着。在常温下,φ=60%以上时可发霉。φ=80%以上则不管温度上下都要发霉。只需有适当的水分(高湿度)。
    The inappropriate control of absolute humidity not only promotes the addition of human germs, but also provides nutrient sources for the reproduction of bacteria. According to research, when absolute humidity is 50%, bacteria will die after 10 minutes of plankton; when absolute humidity is higher or lower, even after 24 hours, most bacteria are still alive. At room temperature, moulds can occur when the ratio of_ = more than 60%. If the temperature is above 80%, it will be mildewed regardless of the temperature. Only proper moisture (high humidity) is required.
    细菌就可以在零碎中随时随地繁衍。初会形成整个控制失败,对温、湿控制不当的危害应惹起高度注重。另外,夏季污染手术室内湿渡过低还会发生静电。对医疗器械如心电监护仪的正常运用和患者的平安构成要挟。
    Bacteria can multiply in fragments anytime, anywhere. Initially, the whole control will fail, and the harmfulness of improper temperature and humidity control should arouse great attention. In addition, static electricity will also occur in the polluted operating room in summer when the humidity is too low. It poses a threat to the normal use of medical devices such as ECG monitors and the safety of patients.