新闻资讯
  • news
  • 咨询热线:
  • 0531-87568508
  • 18653128690
  • 公司新闻
  • 您现在的位置:首页 > 新闻资讯 > 公司新闻 >
  • 无尘室的一般清洁程序
    来源:http://www.sdyhrs.com 浏览: 发布日期:2017-08-18
    总原则:从上到下,由里到外
    General principles: from top to bottom, from inside to outside
    一般清洁程序:
    General cleaning procedure:
    1.天花板
    1. ceiling
    清洁频率:每月清洁一次。
    Cleaning frequency: clean once a month.
    重症监护室装修公司http://www.sdyhrs.com/清洁方法:将无尘抹布用清水浸湿或用无尘拖把沿直线方向擦抹,避免来回反复抹擦。
    Cleaning method: clean dust-free cloth soaked with water, or wipe with clean mop in a straight line direction, avoid repeated wipe.
    2.墙
    2. wall
    清洁频率:每周清洁一次。
    Cleaning frequency: clean once a week.
    清洁方法:用湿抹布或无尘拖把,由上至下垂直擦拭,擦时按部分重叠的次序。
    Cleaning method: use wet cloth or mop wipe clean, wipe from top to bottom vertical, according to overlapping sequence.
    3.门、框架的部件,墙的清洗
    3. door, frame parts, wall cleaning
    清洁频率:每天清洁一次。
    Cleaning frequency: clean once a day.
    清洁方法:先用半湿抹布擦拭顶部和边缘, 然后再用干抹布清洁门的其它表面。
    How to clean it: first clean the top and edge with a half damp cloth, then clean the other surfaces of the door with a dry cloth.
    重症监护室装修公司
    4.传递窗清洁
    4. transfer window clean
    清洁频率:每周清洁一次。
    Cleaning frequency: clean once a week.
    清洁方法:窗内用半湿抹布从上到下垂直擦洗,然后用干抹布将窗子由上到下抹干。
    Cleaning method: use the semi wet cloth inside the window to scrub vertically from top to bottom, then use dry cloth to dry the window from top to bottom.
    合理的气流组织
    Reasonable airflow organization
    众所周知手术是直接关系到患者的生命安危,手术的发展很大程度上取决于手术感染控制技术的发展。在欧美等发达国家其手术室均采用全空气系统。六十年代初采用ASHRAE指南规定,采用全新风系统。每个手术单元换气次数8-12次。室温25.6度,相对湿度55%。室内排风汇集到排风总管,利用全热交换器热回收后再排出室外。
    It is well known that surgery is directly related to the safety of the patient's life, and the development of the operation depends largely on the development of surgical infection control techniques. In developed countries such as Europe and America, the operation room adopts the whole air system. In early 60s, the ASHRAE guidelines required the use of a new air system. The number of ventilation in each operation unit was 8-12 times. Room temperature is 25.6 degrees, relative humidity is 55%. The indoor exhaust air is assembled into the exhaust main pipe, and the whole heat exchanger is used for heat recovery before being discharged out of the room.
    在手术单元中,顶棚布置过滤器,在两侧距地面不超过500mm处布置回风口,这样能合理地组织室内的气流,防止室内细菌粒子的积聚,并通过合理的气流组织迅速加以排出,保证室内的洁净度。而上送侧回的方式使手术台设置在手术室的中央区域,医生及有关人员在手术台的二侧,气流由上部风口送出,经手术台后再从两侧回,这样能大限度地保证手术台的高度无菌程度。
    In the operating unit, the ceiling layout of high efficiency filters, on both sides from the ground not more than 500mm is arranged at the air outlet flow that can reasonably organize indoor, indoor to prevent bacterial particle accumulation, and through reasonable airflow organization to be discharged quickly, to ensure the cleanliness of the room. And sent back to the side so that the operation platform is arranged in the central region of the operation room, the doctor and the relevant personnel in the operation table two side of the air from the upper air sent by operation station and then back from both sides, this will ensure the maximum height of the sterile degree of operating table.

    上一篇:手术室净化工程的标准确定要求
    下一篇:医院手术室装修设计满足的基本条件