    来源:http://www.sdyhrs.com 浏览: 发布日期:2018-04-11
      静脉用药调配中心(室)的洁净区、辅助工作区应当有适宜的空间摆放相应的设施与设备;洁净区应当含一次更衣、二次更衣及调配操作间;辅助工作区应当含有与之相适应的药品与物料贮存、审方打印、摆药准备、成品核查、包装和普通更衣等功能室。

      The clean area and auxiliary working area of the intravenous dispensing center (room) should have the appropriate space to put the appropriate facilities and equipment; the clean area should contain one change of clothes, two changes of clothing and the operation of the operation; the auxiliary working area should contain the storage of drugs and materials, the print of the trial, the preparation of the medicine and the inspection of the finished products. Functional rooms such as packing and ordinary dressing.

      静脉用药调配中心(室)总体区域设计布局、功能室的设置和面积应当与工作量相适应,并能保证洁净区、辅助工作区和生活区的划分,不同区域之间的人流和物流出入走向合理,不同洁净级别区域间应当有防止交叉污染的相应设施。

      The layout of the overall regional design, the setting and the area of the function room should be adapted to the workload, and can ensure the division of the clean area, the auxiliary working area and the living area, the flow of people and the logistics between different regions is reasonable, and there should be a phase of preventing cross contamination between different areas of clean level. The facilities should be provided.
    静脉药物配置中心

      静脉用药调配中心(室)室内应当有足够的照明度,墙壁颜色应当适合人的视觉;顶棚、墙壁、地面应当平整、光洁、防滑,便于清洁,不得有脱落物;洁净区房间内顶棚、墙壁、地面不得有裂缝,能耐受清洗和消毒,交界处应当成弧形,接口严密;所使用的建筑材料应当符合环保要求。

      There should be enough illumination in the center (room), the color of the wall should be suitable for human vision; the roof, wall and ground should be smooth, clean, skidproof, easy to clean, and not to have shedding; the roof, wall and ground in the room of the clean area can not be cracked, and can withstand the cleaning and disinfection. It should be arc-shaped and tightly interfaced, and the building materials used should meet the requirements of environmental protection.

      静脉用药调配中心(室)应当设于人员流动少的安静区域,且便于与医护人员沟通和成品的运送。设置地点应远离各种污染源,禁止设置于地下室或半地下室,周围的环境、路面、植被等不会对静脉用药调配过程造成污染。

      Intravenous drug dispensing center (room) should be located in a quiet area with fewer personnel flow, and it is easy to communicate with medical staff and transport products. The setting should be kept away from all kinds of pollution sources, and it is forbidden to set in the basement or the semi basement. The surrounding environment, the pavement, the vegetation and so on will not cause pollution to the process of intravenous administration.

      静脉用药调配中心(室)洁净区应当设有温度、湿度、气压等监测设备和通风换气设施,保持静脉用药调配室温度18℃~26℃,相对湿度40%~65%,保持一定量新风的送入。

      There should be temperature, humidity, air pressure and other monitoring equipment and ventilation facilities in the clean area of the intravenous dispensing center (room). The temperature of the intravenous dispensing room should be maintained at 18 to 26 degrees C, and the relative humidity is 40% ~ 65%, so as to maintain a certain amount of fresh air.

      以上便是静脉药物配置中心今天的分享,您还满意吗,欢迎关注我们的网站:http://www.sdyhrs.com/并且关注我们的产品,我们将为您提供优良的产品,衷心的愿与您建立合作关系。

      The above is the sharing of venous drug distribution center today, are you satisfied, welcome to our website: http://www.sdyhrs.com/ and pay attention to our products, we will provide you with excellent products, and sincerely wish to establish a cooperative relationship with you.

    上一篇:层流手术室可达到防止手术感染的目的
    下一篇:单向流洁净室原理则就是靠推出作用