新闻资讯
  • news
  • 咨询热线:
  • 0531-87568508
  • 18653128690
  • 行业新闻
  • 您现在的位置:首页 > 新闻资讯 > 行业新闻 >
  • 手术室净化工程的五大特点
    来源:http://www.sdyhrs.com 浏览: 发布日期:2018-12-07
    手术室净化工程的五大特点
    Five Characteristics of Operating Room Purification Project
    1、迷信污染杀菌,空气干净度99.98%层流手术室普通采用空气污染层流安装,将空气中的尘埃粒子和细菌停止过滤、消毒。层流手术室层流手术室每立方米沉降菌少于2个,空气干净度高达99.98%,室内恒温、恒湿、恒压,每小时换气600次,可以根绝因手术环境招致的手术感染,进步手术质量。
    1. Superstitious pollution sterilization. The laminar flow operating room with 99.98% air cleanliness is usually installed with air pollution laminar flow. Dust particles and bacteria in the air are filtered and disinfected efficiently. Laminar flow operating room has less than 2 sedimentation bacteria per cubic meter, and the air cleanliness is as high as 99.98%. Indoor constant temperature, humidity and pressure, 600 breaths per hour, can eradicate surgical infection caused by operating environment and improve the quality of operation.
    手术室内每分钟数十次空气循环污染,恒温、恒湿、恒压和噪声控制均经过空气污染零碎来完成,层流污染手术室人流、物流严厉分开,手术室特设污物通道,扫除一切外源性净化,这大水平上避免了细菌、灰尘对手术室的净化。
    Dozens of air circulation pollution per minute in the operating room, constant temperature, humidity, constant pressure and noise control are completed through air pollution fragments. Laminar flow pollution of the operating room is severely separated from the flow of people and logistics. The operating room has a special sewage passage to remove all exogenous purification, which avoids bacteria and dust on the greatest level to the operating room. Purify.
    2、正压气流感染率简直爲零,层流手术室经过过滤器装在手术病床的正上方,气流垂直吹送,回风口设在墙面的四角,确保手术台干净达标。在手术室内的顶部还设置了一个吊塔式的负压吸引零碎,将医生呼出的空气吸出塔外,进一步保证手术室的干净和无菌,层流手术室正压气流爲(+23-25Pa),避免外来净化进入。使感染率几近爲零。从而无效防止了传统手术室温度时高时低,医护人员常受搅扰,成功防止了术中感染状况的发作。
    2. The positive airflow infection rate is almost zero. The laminar operating room is installed directly above the operating bed through a high-efficiency filter. The airflow is blown vertically and the return air outlet is set at the four corners of the wall to ensure that the operating table is clean and up to the standard. At the top of the operating room, a suspension tower type negative pressure suction piecemeal is set up to suck the doctor's exhaled air out of the tower to further ensure the cleanliness and sterility of the operating room. The positive pressure air flow in the laminar flow operating room is (+23-25Pa) to avoid external purification. Make the infection rate close to zero. Thus ineffective to prevent the traditional operating room temperature when high or low, medical personnel are often disturbed, successfully prevent the onset of infection during the operation.
    手术室装修
    3、可供舒适的气流,层流手术室中空气采样设内、中、外对角线3点,内、外布点部地位距墙面1 m,位于层流出风口下;术中空气采样选择手术床4角,距手术床30 cm处。活期检测层流零碎功用形态,检测手术室空气干净度目标,可供舒适的气流(室内温度可在15-25℃,湿度可在50-65%之间调理)。
    3. For comfortable air flow, the air sampling in laminar operating room is set at three points, i.e. the diagonal line of inside, middle and outside, the position of the inner and outer points is 1 m away from the wall and under the laminar outflow vent. During the operation, the air sampling is selected at four corners of the operating bed and 30 cm away from the operating bed. Current detection of laminar fragmentary functional form, detection of operating room air cleanliness target, for comfortable air flow (indoor temperature can be 15-25 degrees C, humidity can be adjusted between 50-65 percent).
    4、低细菌数及低麻醉气体浓度,层流手术室空气污染零碎在手术室墙面四角、污染机组、天花板、走廊、新风机、排风机都设有不同级别的过滤器,并对其停止活期清洁、维修和改换,严厉保证室内空气的无菌;使层流手术室坚持低细菌数及低麻醉气体浓度。
    4. Low bacterial count and low concentration of anaesthetic gas. Air pollution in laminar operating room is fragmented. There are filters at different levels in the four corners of the wall, contamination unit, ceiling, corridor, fresh air fan and exhaust fan of the operating room. They are cleaned, maintained and replaced during the active period to ensure the sterility of indoor air strictly. Low bacterial count and low anesthetic gas concentration were maintained.
    5、共同的设计使细菌无处藏身,层流手术室采用全无缝出口塑胶地板、不锈钢墙面,室内墙角全部爲弧形构造设计,层流手术室找不就任何一个90°的墙角,使细菌无处藏身,防止了肃清不尽的死角,并且室内无须运用物理或化学办法停止消毒,这样既节省休息又避免外来净化的进入。
    5. The common design makes bacteria nowhere to hide. Laminar flow operating room adopts plastic floor with seamless outlet and stainless steel wall. The interior wall corners are all arc-shaped structure design. Laminar flow operating room can not find any 90 degree wall corners, which makes bacteria nowhere to hide, prevents endless dead corners from being cleaned up, and there is no need to use physics or chemistry in the interior. Learn to stop disinfection, so as to save rest and avoid the entry of external purification.
    综上所述有山东净之源净化工程有限公司提供,想了解更多手术室装修知识,欢迎关注我们的网站:http://www.sdyhrs.com谢谢支持!
    In summary, all the above-mentioned Shandong Jingzhiyuan Purification Engineering Co., Ltd. provides, want to know more about operating room decoration knowledge, welcome to pay attention to our website: http://www.sdyhrs.com Thank you for your support!

    上一篇:层流手术室装修施工方案
    下一篇:重症监护室装修根本要求: