    来源:http://www.sdyhrs.com 浏览: 发布日期:2019-06-12
    静脉药物配置中心(PIVAS)是静脉用药集中配置场所,加强对PIVAS的医院感染管理,对保障临床用药安全和预防控制医院感染,具有极其重要的作用与意义。静脉药物配置中心装修公司提示大家,PIVAS的医院感染管理应该特别注重布局流程的管理!具体要求如下:
    The intravenous drug allocation center (PIVAS) is a centralized place for intravenous drug use. Strengthening the management of hospital infection in PIVAS plays an extremely important role in ensuring the safety of clinical drug use and preventing and controlling hospital infection. PIVAS Hospital Infection Management should pay special attention to the layout process management. Specific requirements are as follows:
    (一)总体区域设计布局、功能室的设置和面积应当与工作量相适应,并能保证洁净区、辅助工作区和生活区的划分,不同区域之间的人流和物流出入走向合理,不同洁净级别区域间应当有防止交叉污染的相应设施。
    (1) The overall layout of the regional design, the setting and area of the functional rooms shall be compatible with the workload, and the division of the clean areas, auxiliary working areas and living areas shall be ensured. The flow of people and logistics between different areas shall move towards a reasonable direction. The corresponding facilities for preventing cross-contamination shall be provided between regions of different cleanliness levels.
    (二)应当设于人员流动少的安静区域,且便于与医护人员沟通和成品的运送。设置地点应远离各种污染源,禁止设置于地下室或半地下室,周围的环境、路面、植被等不会对静脉用药调配过程造成污染。洁净区采风口应当设置在周围30米内环境清洁、无污染,离地面高度不低于3米。
    (2) It should be located in quiet areas with less mobility of personnel and be convenient for communication with medical staff and transportation of finished products. Setting place should be far away from all kinds of pollution sources. It is forbidden to set up in basement or semi-basement. The surrounding environment, road surface and vegetation will not pollute the intravenous drug dispensing process. The air intakes in clean areas should be set within 30 meters of the surrounding environment, clean and pollution-free, and not less than 3 meters above the ground.
    (三)洁净区、辅助工作区应当有适宜的空间摆放相应的设施与设备;洁净区应当含一次更衣、二次更衣及调配操作间;辅助工作区应当含有与之相适应的药品与物料贮存、审方打印、摆药准备、成品核查、包装和普通更衣等功能室。
    静脉药物配置中心装修
    (3) Clean areas and auxiliary working areas shall have suitable space for the appropriate facilities and equipment; clean areas shall include one-time changing, two-time changing and dispensing operation rooms; auxiliary working areas shall contain suitable functional rooms for the storage of drugs and materials, the printing of examining parties, the preparation of dispensing drugs, the verification of finished products, packaging and general changing.
    (四室内应当有足够的照明度,墙壁颜色应当适合人的视觉;顶棚、墙壁、地面应当平整光洁、防滑,便于清洁,不得有脱落物;洁净区房间内顶棚、墙壁、地面不得有裂缝,能耐受清洗和消毒,交界处应当成弧形,接口严密;所使用的建筑材料应当符合环保要求。
    (Four rooms should have sufficient illumination, wall color should be suitable for human vision; roofs, walls and floors should be smooth, smooth and smooth, non-slippery, easy to clean and no falling objects; roofs, walls and floors in clean areas should not have cracks, can withstand cleaning and disinfection, the junction should be curved, the interface should be tight; the building materials used should meet the requirements of environmental protection. 。
    (五)应当设有温度、湿度、气压等监测设备和通风换气设施,保持静脉用药调配室温度18℃~26℃,相对湿度40%~65%,保持一定量新风的送入。
    (5) Temperature, humidity, air pressure and other monitoring equipment and ventilation and ventilation facilities shall be provided to maintain the temperature of the intravenous drug dispensing room from 18 to 26 degrees and the relative humidity from 40 to 65 percent, and to maintain a certain amount of fresh air.
    (六)洁净区的洁净标准应当符合国家相关规定,经法定检测部门检测合格后方可投入使用。
    (6) The cleanliness standards of clean areas shall conform to the relevant provisions of the State, and shall not be put into use until they are qualified by the statutory inspection departments.
    (七)应当根据药物性质分别建立不同的送、排(回)风系统。排风口应当处于采风口下风方向,其距离不得小于3米或者设置于建筑物的不同侧面。
    (7) Different delivery and drainage (return) air systems shall be established according to the nature of the drug. The exhaust outlet shall be in the downwind direction of the exhaust outlet, and its distance shall not be less than 3 meters or set on different sides of the building.
    (八)药品、物料贮存库及周围的环境和设施应当能确保各类药品质量与安全储存,应当分设冷藏、阴凉和常温区域,库房相对湿度40%~65%。二级药库应当干净、整齐,门与通道的宽度应当便于搬运药品和符合防火安全要求。有保证药品领入、验收、贮存、保养、拆外包装等作业相适宜的房屋空间和设备、设施。
    (8) Drugs and materials storehouses and their surrounding environment and facilities should ensure the quality and safety of all kinds of drugs. They should be separated into refrigerated, shady and normal temperature areas, with relative humidity of 40%-65%. Secondary drug stores should be clean and tidy, and the width of doors and passages should be easy to carry drugs and meet fire safety requirements. There are suitable housing space, equipment and facilities to ensure the operation of drug import, acceptance, storage, maintenance, dismantling and packaging.
    (九)静脉用药调配中心(室)内安装的水池位置应当适宜,不得对静脉用药调配造成污染,不设地漏;室内应当设置有防止尘埃和鼠、昆虫等进入的设施;淋浴室及卫生间应当在中心(室)外单独设置,不得设置在静脉用药调配中心(室)内。
    (9) The location of the water pool installed in the intravenous drug dispensing center (room) shall be appropriate, and no pollution or floor leakage shall be caused by the intravenous drug dispensing; facilities for preventing dust, mice and insects shall be installed indoors; showers and bathrooms shall be installed separately outside the center (room) and not in the intravenous drug dispensing center (room).
    本文来自:静脉药物配置中心装修公司,更多的内容请点击:http://www.sdyhrs.com我们将会为您提问的问题提供一个满意的服务,欢迎您的来电!