    来源:http://www.sdyhrs.com 浏览: 发布日期:2020-07-21
    现在医院采用了大量的手术室净化,这种设备拥有更先进的技术,建成了手术室净化。随着手术室净化和净化项目的不断发展,越来越多的人为人们提供服务。如果您想了解更多,您可以从以下几个方面了解手术室净化的准备。
    Now the hospital has adopted a large number of operating room purification, this equipment has more advanced technology, built operating room purification. With the continuous development of operating room purification and purification projects, more and more people provide services for people. If you want to know more, you can learn about the preparation of operating room purification from the following aspects.
    医院手术室净化
    Hospital operating room purification
    进入手术室前,应将各种仪器设备安装完毕并擦拭干净。擦拭时,不建议将失去纤维的织物材料用作清洁工具。作业结束后,应立即清除各种污垢,并将其分为防水、防污袋,密封后从污物通道中运出。擦拭各种设备,整理手术室,避免长期呆在室内的灰尘污染空气。
    Before entering the operating room, all kinds of instruments and equipment should be installed and cleaned. When wiping, it is not recommended to use fabric material that has lost fiber as a cleaning tool. After the operation, all kinds of dirt should be removed immediately and divided into waterproof and antifouling bags, which should be transported out of the dirt channel after sealing. Wipe all kinds of equipment and clean the operating room to avoid air pollution caused by dust in the room for a long time.
    当所有人员离开,清洁工作完成后,手术室空调系统应继续运行15-20分钟,然后关闭层流空调,使室内空气洁净。每天在手术前后,用消毒剂对无影灯、仪器车、麻醉台、手术台、壁柜等设备的表面和地面擦拭一次,对工作人员穿的隔离鞋进行清洁消毒。
    Air conditioning should be turned off for 15 minutes after the air conditioning system is finished, and then the air conditioning system should be turned off when the operating room is clean. Before and after the operation, wipe the surface and ground of shadowless lamp, instrument car, anesthesia table, operating table and wall cabinet with disinfectant once a day, and clean and disinfect the isolation shoes worn by the staff.
    每周对上述设备及地面进行一次清洁保养。粗滤器、中滤器、回风口各清洗一次,保证滤尘效果。粗滤器、中效过滤器、回风网每2周定期用500mg/L含氯消毒剂()湿洗,无菌切口感染率小于或等于0.2%。每月对洁净手术部的空气和设备表面进行细菌培养取样,检测粉尘粒子数、噪声、温度和湿度,并对结果进行登记归档。粗滤器和中间滤器每6个月更换一次。每年更换过滤器。
    Clean and maintain the above equipment once a week. Clean the coarse filter, intermediate filter and return air inlet once to ensure the dust filtering effect. The coarse filter, medium efficiency filter and return air net were washed with 500mg / L chlorine containing disinfectant (high efficiency) every two weeks. The infection rate of aseptic incision was less than or equal to 0.2%. Bacterial culture samples were taken from the air and equipment surface of clean operating department every month to detect the number of dust particles, noise, temperature and humidity, and the results were registered and filed. The coarse filter and intermediate filter should be replaced every 6 months. Replace the high efficiency filter every year.
    以上是医院手术室净化的准备工作,手术室净化的应用简化了医院管理人员,大大提高了安全,同时提高了经济效益,如果你有任何问题,请打电话咨询。,
    The above is the preparation work of the hospital operating room purification. The application of operating room purification simplifies the hospital management personnel, greatly improves the safety, and improves the economic benefits. If you have any questions, please call for advice. ,

    上一篇:静脉药物配置中心装修需要知道的要求